Bentley Raceway and Cable Management CONNECT Edition Help

New and Changed in Bentley Raceway and Cable Management CONNECT Edition Update 5

The following topics summarize the new features and enhancements in the Bentley Raceway and Cable Management CONNECT Edition Update 11 release.

OpenPlant Modeler Integration

The Bentley Raceway and Cable Management Raceway and Underground System design tools are integrated with and can be optionally installed with OpenPlant Modeler.

Note: To utilize cable management features you will need to use this standalone Bentley Raceway and Cable Management application.

Components Center Integration Moved from Technical Preview to Commercial Release

Components Center is a cloud-based digital component library and catalog management service. It allows users to efficiently manage their digital component libraries while providing their designers with approved, proprietary components as well as manufacturer's content via subscriptions.

Cell-based equipment can now be stored as components in Components Center. The Equipment Manager allows you to place cells from Components Center in addition to local or shared cell libraries in a WorkSpace.

Components Center integration is enabled in the Options > Components Center dialog by selecting the Enable Components Center checkbox.

New Formalized SDK

Bentley Raceway and Cable Management includes a public API that allows you to automate the placement of equipment. During the product installation you can elect to install the Product SDK which provides you with a help file document explaining how to use the API and an example program that demonstrates how you can use the equipment placement API.

Enhanced Ribbon Menu

New Contextual Ribbon Menu Tools

We added some common modification tools that were missing from the contextual ribbon menus when selecting Raceway and Duct Bank objects. These tools include:
  • Raceway Size
  • Insert Part
  • Delete Raceway
  • Move
  • Copy
  • Duct Bank Properties
  • Modify Duct Bank
  • etc.

New Help Ribbon Tab

We added a help ribbon tab that gives you quick access to various help resources including:

New/Changed Option Settings

Several changes have been made to the software options which include:

A new Air Gap Distance setting allows you to adjust the routing connection tolerance which was previously hard coded to 10mm.

Status Management Options Clarified
  • We deprecated and removed the unused Equipment Import Status Manager Settings.
  • We renamed the "Modification" toggle to "Lock" in order to clarify the meaning of the toggle.

2D Extraction Section Table Enhancements

Dynamically Sized 2D Extraction Section Tables

Creating 2D Extraction tables now automatically detects whether you are placing the table in a model or a sheet and adjusts the size of the table accordingly.

We have introduced a new Text Style for 2D extraction tables that is properly sized for models and each CSECTION*.xml file has separate text style and size settings depending on whether the table will be placed in a model or a sheet.

Include Cable Types in 2D Extraction Section Tables

You can now display cable types in 2D Extraction section tables.

We created a new predefined variable named "$(cabletype_items)" which can be added into the legend category of any of the cross section template files as shown here:

This variable will report the cable types of all cables found in the cross section as shown here:

Note: The $(rw_id) variable must be present in the same table in order for the $(cabletype_items) variable to work.

Visualize Highlighted Raceway Systems

You can now reference your raceway model into your routing model and Visualize a cable route to highlight the raceways the cable was routed through. Previously it only highlighted the routing line which was harder to see.

New Isometric Cable Route Report

A new cable route report template has been created which includes visualizations of the cable route taken. The Output Manager now includes an Export Images tool that automatically creates the cable route visualizations and captures images of them and saves them to the path specified in a new configuration variable named, "BRCM_IMAGE_PATH." When you then run the cable route report it includes those images for each cable included in the report as shown here:

New Support for Product Code Calculations

We have added additional capabilities to generate product codes for raceway parts by allowing you to perform mathematical calculations on different variables that can be used in the product code.

Syntax Rules:
  1. You must surround any calculation with curley brackets "{}."
  2. You must surround each variable with its own set of parenthesis "( )."

i.e. < PCode Value="RWEB ${($ VATradeWidth ) - ($RT)} ($ UTMaterial )" />

New Equipment ID Filters in Bill of Quantity (BOQ) Report

The Detail_BOQ_WithEquipmentID report template now supports filtering on the Equipment ID as shown here:

OpenPlant Modeler iModel Equipment Import Schema Location Changed

The OpenPlant_Supplemental_Mapping_BRCM.01.07.ecschema will no longer be located in the "ECSchemas" folder of the installation path:

"C:\Program Files\Bentley\Bentley Raceway and Cable Management CONNECT Edition\BRCM

This schema now is placed under the dataset in the workspace. For example, the Metric dataset:

C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\schemas.

Enhanced iModel Import for OpenPlant Modeler Equipment

You now have the ability to specify the electrical device insertion point for your OpenPlant Modeler equipment as a new property in the OPM iModel schema. The property name is user definable and configurable in OpenPlant Modeler by setting this new configuration variable to the name of the property you want to use:

BRCM_OPM_CABLE_CONNECTION

By default it is configured as follows:

Property Name Value
ELECTRICAL_DEVICE_OFFSET X,Y,Z (This is the offset from the insertion point of the equipment to where the electrical device should be located.

When the iModel is imported into Bentley Raceway and Cable Management the software will check this property to see if it has an offset specified and if so it will place the electrical equipment such as a junction box at this offset. If this property is not found or has no value the electrical equipment will be inserted at the same insertion point as the OpenPlant Modeler equipment.

New Raceway Divider Capacity Settings

When adding dividers to your raceway systems you now have the option to specify the capacity of the dividers based on cable quantities. A new picklist allows you to select a "<Dynamic>" entry that will automatically calculate the size of the sections created by the divider in order to allow the maximum number of cables to be routed. This new picklist also allows you to select commonly used capacity percentages so that you can quickly set the capacity.

Raceways Mended When Fittings are Deleted

When a Tee fitting is deleted the straight part of the raceway system will be automatically mended. Similarly, when a Crossover fitting is deleted the raceways will be mended in both directions so that you can then consider adding an elevation to one of the systems to avoid the overlap.

Bulk Load Raceway UDAs into the Raceway Router Tool

You now have the ability to import multiple UDA values into the Raceway Router dialog prior to routing raceway. This feature saves you time by allowing you to predefine commonly used UDA values and load them in bulk before routing raceways.

Dataset Updates

Dataset Changes made for Update 5 can be found in the CFG_Properties.xml under each WorkSpace.

i.e. C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Imperial Example\Standards\BRCM\std_dataset\metadata\CFG_Properties.xml

The specific changes in this version can be found under version 3.5 as shown below:

Important! Dataset Files Renamed

We renamed the default CAT and DNA files in the standard datasets to shorten the filenames to avoid exceeding the Windows 255 character limit on file paths. We employed the various abbreviations explained below when renaming the files. You can find a "FileNameMappings.csv" file that contains a list of the original filenames and the new updated filenames within each WorkSpace's Raceway Dataset folder.

i.e. C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Imperial Example\Standards\BRCM\std_dataset\raceway

Folder Name Changes

BRCM Imperial Example\Standards\BRCM\std_dataset\raceway\Templates\
  • RWE_Template_Imperial_Cable_Basket > Basket
  • RWE_Template_Imperial_Cable_Ladder > Ladder
  • RWE_Template_Imperial_Cable_Tray > Tray
  • RWE_Template_Imperial_Conduit > Conduit
BRCM Metric Example\Standards\BRCM\std_dataset\raceway\Templates
  • RWE_Template_Metric_Cable_Basket > Basket
  • RWE_Template_Metric_Cable_Ladder > Ladder
  • RWE_Template_Metric_Cable_Tray > Tray
  • RWE_Template_Metric_Conduit > Conduit
File Abbreviations
  • Aluminum > AL
  • Angular > Angle
  • Back > BCK
  • Bottom > BOT
  • Beveled > BEV
  • Branch > BR
  • Cable_Basket > Basket
  • Cable_Tray > Tray
  • Cable_Ladder > Ladder
  • Chamfered > CH
  • Champer > CH
  • Concrete > CONC
  • Common > comm
  • Conduit > CND
  • Crossover > CRSVR
  • Down > DN
  • Dynamic > DYN
  • Electrical_Metallic_tuing > EMT
  • Expanding > EXP
  • Fitting > PT
  • Flexible > Flex
  • Galvanized > GV
  • Glass Fiber Reinforced > GFR
  • Heavy_Duty > Hvy_Dty
  • Hinge > HNG
  • Horizontal > H
  • Inside > Ins
  • Intermediate > INTER
  • Junction-box . JB
  • Large > LG
  • Left > L
  • Long Span > LS
  • Nonmetallic > NM
  • Outside > Out
  • Perforated > PERF
  • Profile > Pro
  • Reducer > Rdcr
  • Right > R
  • Rounded > Rnd
  • Schedule > SCH
  • Square > SQ
  • Series > SER
  • Small > SM
  • Straight > STR
  • Steel > ST
  • Stainless Steel > SS
  • Through > Thru
  • Trough > Thru
  • Top > T
  • Up > U
  • Ventilated > VNTD
  • Vertical > V
  • Wireway > ww
  • Zinc > Zn